HDI Series

Product Overview

HDI Series Cordless Shut-off Tool  Impact Tool

Recommended Torque Range3~120Nm (for soft joints)
Cordless TypeBattery-operated
Torque Accuracy(reference only)Mechanical shut-off with ±20% tolerance, managed by the number of impacts
Long Service LifeBrushless motor
Adoption of contactless switch
Fastening speed3 stages adjustable
Free speed2,400 min̠⁻1

LINEUP

スクロールできます
ModelCapacity(Nominal Bolt Size)Drive Size
(Sq. or Hex. Size)
Torque RangeFree speedWeight w/o Battery
MinimumMaximum
mminNmNmmin-1kg
HDI-5M5~M66.351/432524001.0
HDI-6DM6~M86.351/463224001.0
HDI-6M6~M89.53/863224001.0
HDI-8M8~M109.53/8155524001.1
HDI-8AM8~M1012.71/2155524001.1
HDI-10M10~M1212.71/22510024001.1
HDI-12M12~M1412.71/23012024001.2

*Torque range is a guideline only. Please select tool appropriately according to actual application.
*Model number does not include battery or battery charger. Please order battery and/or battery charger separately.

Peripherals for tools

HDI Tool

Shut-off Impact Tool

Programmer(P-PG)

Perform tool settings

Battery Pack and Charger

The battery is a 2Ah model (375g)with a power remaining meter

Features

01.LED Display

02. Impact Count Setting

Impact count can be adjusted in up to 50 levels.
00: No shut-off
1 to 50: Increasing the number increases the impact count
The impact count per level can be set from 1 to 5 impacts (see example table on the right).​

【Example of Impact Settings】

 Impact counts per stage
12345
Stage155555
Stage2678910
Stage379111315
Stage4811141720
Stage5913172125
Stage61015202530
Stage71117232935

Impact count can be freely set up to a maximum of 150 impacts.

03. Rotation Direction Setting

You can set it for either clockwise or counterclockwise rotation. It also supports left-handed screws

04. Rotation Speed Setting

High speed mode: 2400 rpm
Medium speed mode: 2000 rpm
Low speed mode: 1500 rpm
You can set it to one of these three rotation speeds.
If the screw is refastened after fastening, the LED will light up in red for one second with a long beep for one second.。​

05. Reverse Rotation Setting

  1. The number of rotations during reverse operation can be preset.
  2. This setting defines how many turns to perform—not the rotation speed.
  3. It is useful when loosening a bolt but stopping before the bolt is completely removed.

06. Switch Operation Setting

Enables locking of the forward/reverse rotation switch and the impact count setting button.
You can disable the switch function to prevent accidental operation during reverse rotation.

07. LED Irradiation Time Setting

The LED lighting that illuminates the forward workpieces can be freely set for a duration of 0 to 60 seconds for both forward and reverse operations.

08. Buzzer Volume Adjustment

To alert operators to fastening errors, notifications are provided not only through LEDs but also via a buzzer. The buzzer volume can be set to one to four levels: silent, low, medium, or loud.

09. Recommended Torque